Knowledgebase : DSC
By default the AC status indicator does not light up on DSC keypads. There is an option in programmi...
To adjust DSC alarm system entry and exit delays: *8 (installer code) type in 005 for section 5 th...
First please triple check that the PCLINK serial board is plugged in correctly as it is possible ...
Symptom: DSC Alarm panel is set to residential dial to a private phone or cellular phone.  When th...
If you will not be connecting your DSC alarm system to a telephone line, you need to ensure that it ...
DLS runs on Microsoft's .NET Framework 4.0 and now using SQLite database. If you do not currently ha...
Home and Business owners looking for documentation or user manuals for DSC equipment or help iden...
DSC PC1555MX Installation manual
Download may be found here: Power832 PC5010 Installation Manual [1] Links: ------ [1] http://...
If you wish to have the DSC PK5501 / RFK5501 keypad show open zones automatically, turn on Option 8 ...
If you'ved decided on DSC, this guide will help you determine what you need. There are three main ...
By default, DSC Powerseries wired panels are expecting each zone to have EOL resistors installed. If...
DSC Powerseries alarms can call out using a landline telephone connection, to an ouside telephone or...
If you wish to have your DSC Alexor alarm system use residential dial (self monitoring) be sure to...
As of the time of writing (Aug 27th 2010) the RM-1 wiring is as follows: Black - negative coil Re...
Note: Default installer code is 5555 1. Enter [ ✱ ][8][Installer Code][898]. The LCD displays the ...
Wireless keyfobs need to be enrolled in slots 41 through 56 with the first key in 41, second key...
How to enroll wireless devices in to a DSC alarm system using a PK5501 or RFK5501 keypad by manually...
Some device ESN contain LETTERS. In this case, use the following sequence to represent that letter ...
If you have lost or forgotten your installer code for Powerseries (PC1616/PC1832/PC1864) and need ...
Q: Is there an alarm system I can purchase which I can seemlessly connect with my insteon system? ...
Keep in mind that DSC Powerseries wired alarms can provide up to 700mA current to connected devices....
The programming instructions for labelling zones on a PK5500 keypad are found in the keypad manual (...
Quick Guide To Programming DSC Powerseries Alarm Panels The following guide outlines the basic prog...
In case you accidentally program the partition or other settings incorrectly in the keypad or you...
Please see the pdf attachment listed below, for instructions to set the time on various DSC alarm pa...
See attached file for all old and current DSC alarm systems. The time will need to be set during a...
If there is nothing programmed in your wireless receiver, then you will not see 17 in section 903...
As practically all alarm companies are supporting some sort of automation, typically Zwave devices, ...
WHAT DOES THE YELLOW TROUBLE LIGHT ON MY DSC KEYPAD MEAN? The yellow trouble light indicates a sys...
2 wire smoke detectors connect with only 2 wires back to the panel, and can only be connected to th...
Wireless motion sensors from DSC, Elk, Honeywell, Resolution, etc are designed to trip once when ...
The manual can be a bit confusing.. for basic operation: Terminal 1 - 12VDC Power + Terminal 2 P...
If you're having issues enrolling a new WTK5504 or WTK5504P keypad in your DSC powerseries system, t...