At time of writing, there is no such thing as a 120V or 240V thermostat from any automation vendors ...
While there is no official blackberry application for the 2412N, it is possible to access the 241...
Although the temperature readings from the factory are normally accurate, if you find your thermo...
> Are there any light switches that are available that dont require the neutral wire. > Most aut...
Most Insteon devices can accept an X10 code and can be controlled by an X10 wired transmitter.  Ho...
You can change a 2486DWH6 in to a 2486DWH8, or vice verse, by replacing the front cover plate with...
The Insteon Hub is good for small jobs or basic needs like remotely switching lights on/off, and sim...
The Insteon Hub is a stand alone automation controller for Insteon devices. It plugs in to the netwo...
The 2412N SmartLinc was designed as a simple Insteon controller with some support for X10.  It ha...
Pull the set button out completely, let it stay out for 10 seconds. Push it back in PAST THE NORMAL ...
HOW DO I KNOW IF I HAVE A NEUTRAL WIRE? Most INSTEON-compatible wall switches and dimmers require ...
While HouseLinc software is no longer being developed, Insteon is still trying to add support for ne...
If your Insteon 2474 2 wire dimmer stops working, first check the breaker to ensure there is power t...
Circuites with panel mounted GFCI circuit breakers,  particular older models, can falsely trip whe...
The Insteon 2477D dimmer is officially rated for incandescent lighting only. However we've seen many...
> I am interested in buying the INSTEON Garage Door Control and Status Kit below. > Do you know if ...
For Insteon support and troubleshooting there is a dedicated toll-free support telephone number se...
Insteon released a new Insteon Hub V2 (2245-222) some time ago and has been offering an upgrade prog...
Q: Is there an alarm system I can purchase which I can seemlessly connect with my insteon system? ...
Insteon dimmers and switches can easily be linked so they can control each other. When linking devic...
For a 3 way (2 switches) or 4 way (3 switches) circuit, you need to replace both/all switches wit...
INSTEON direct technical support may be reached by any of the following: Tel: 866-243-8022 or ...
Aluminum wiring is less conductive then copper so the INSTEON signal may be slightly affected by ...
It is possible for an Elk M1 Gold to 'see' Insteon status and also control Insteon devices throug...
The Insteon IOLinc can provide basic integration to an alarm system from DSC, GE, Visonic, etc. Mo...
If you get a message from the ISY console that it is operating in safe mode, this means it is hav...
If you are trying to link a new device to the ISY994 and get a message 'Cannot Determine Insteon Eng...
Some INSTEON products like LampLinc or OutletLinc Dimmer are designed for incandescent lighting, lik...
Regurgitated from Indigo's support site. The MorningLinc controller uses RF to control locks and de...
EZFLORA can be controlled by an automation controller like the ISY99 or ISY994 series. The controlle...
The ISY99 and ISY994 series from Universal Devices can have additional capabilities added by purc...
ISY99 / ISY994 has an add-on 'Network Module' available for purchase directly from Universal (sof...
If you are finding that the SmartLinc 2412N is losing time or not keeping exact time, please refer...
If you do not have a neutral wire at the wall switch location controlling a light, this means that y...
> I have an ISY994iZIR and I wondering if it's compatible with Skylink device Switch or other domoti...